- No. de Modelo: EN500-4T2200G/2500P
- Aplicación : Transductor de Alto Rendimiento , Transductor de Fase Tres
- Tipo de salida : Tres Vías
- Principio del trabajo : Control de Transductor de Vector
- Principal Tipo de circuito : Tensión
- Voltaje de fuente de alimentación : High Voltage Drive de frecuencia variable
- Enlace de la Transformación : AC-DC-AC Drive de frecuencia variable
- Naturaleza de alimentación de CC : Tensión Drive de frecuencia variable
- Función : Tipo simple
- Trademark: ENC
- Packing: Carton
- Standard: ISO9001: 2000, EN61800-5-1: 2003, EN61800-3: 2004
- Origin: China
- HS Code: 85044090
- Production Capacity: 17000PCS/Month
Las descripciones de la norma EN500 universal multifuncional convertidor de frecuenciacomo el salvado de un nuevo vector universal multifuncional CONVERTIDOR DE FRECUENCIA, ES500 es más sofisticado que el anterior los convertidores de frecuencia; da OEM, los constructores de máquinas y usuarios finales de rendimiento: mejorar el control del motor de una manera fácil de usar y paquete compacto. EN500 adopta la tecnología líder de la tecnología y control de vectores, que puede proporcionar el rendimiento potente a los usuarios finales. Lo más importante es que EN500 cada vez más inteligente. Y el gabinete/integración de tipos de montaje en pared diseño puede ayudar a los usuarios instalar convenientementeventajas de rendimiento de la norma EN500 universal multifuncional convertidor de frecuencia1. Con la auto-aprendizaje, seguimiento, y patinaje de velocidad de la función de control de vectores;2. Compacto, fácil de instalar, y el alto costo de rendimiento;3. Completa el inversor de vectores de universal, el gabinete/montaje en pared typeintegration diseño;4. En el reactor integrada estándar para el tipo por encima de 90kw (interno);5. Función de extensión periférica abundantes: bus, terminal, relé, una extensión analógica;6. Los usuarios de abundantes características: suministro de agua a presión constante, atravesar el control, control de la reducción y control de longitud fija, etc.7. La función de comunicación abundante: Libre protocolo, protocolo Modbus, Profibus, CAN bus ampliado y etc. Laindustria de la aplicaciónse aplica a la maquinaria para trabajar el metal, plástico, maquinaria, diversas máquinas herramienta, la impresión, impresión textil,papel, máquinas automáticas, urbano, ingeniería municipal, Aire Acondicionado, Calefacción, Ventilación constanteabastecimiento de agua a presión constante. Tratamiento de aguas residuales y otras industrias. También puede ser equipado con maquinaria alimentaria, la impresión de lamaquinaria industrial, aire acondicionado, máquinas textiles, el abastecimiento de agua y la reconstrucción de la producción de plástico,fibra de químicos, cemento y cerámica, etc. También es ampliamente demandada en el mercado de la diversión y bomba de dispositivos de información sobre lasindustrias de petrifaction, aceite refinado, la termoelectricidad, suministro de agua, suministro de calor y otras industrias.Grado de tensión: Fase 3 de 380V dealimentación rage: 75kw~400kwcomo profesional ac drive fabricación, hemos venido trabajando en el inversor durante 10 años en China, y de exportación de 7 años de experiencia nos ayuda a obtener una buena palabra de boca en boca de los clientestodos los productos son aprobados por la CE, ISO9001-2008 y en consonancia con las leyes y reglamentos de importación.Todos los productos son cuidadosamente embaladas para asegurarse de que lleguen a ustedes en perfecto estado.Visite el Centro de Soporte de Encom Www.enc.net.cn/en para obtener más información.
item | Item description | ||
Input | Rating volt., frequency | 3 phase 380V:60Hz | |
Allowed volt. range | 320~460V | ||
Output | Voltage | 0~380V | |
Frequency | 0~650Hz | ||
Over load capacity | Gtype:150% of rated current for 1 minute ; Ptype:120% of rated current for 1 minute. | ||
Control performance | Control mode | speed senseless vector control, open loop V/F control | |
Speed regulation range | 1:100 | ||
Start-up torque | 150% of rated torque at 5Hz frequency | ||
Running speed stable state precision | ≤±0.5% of rating synchronous speed | ||
Frequency precision | Digital setting:max. frequency×±0.01% Analog setting: max. frequency×±0.5% | ||
Frequency resolution | Analog setting | 0.1% of max. frequency | |
Digital setting | The precision less than 100HZ:0.01Hz | ||
Exterior impulse | 0.1% of max. frequency | ||
Torque boost | Automatic torque boost, manual torque boost 0.1~12.0% | ||
V/F curve(volt. frequency characteristic) | Set rating frequency randomly at range of 5~650Hz,can choose constant torque, 1,degressive torque 2,degressive torque 3,user defined V/F curve in total 5 kinds of curve | ||
acceleration and deceleration curves | 2 modes: linear acceleration and deceleration and "S"acceleration and deceleration; 15 types of acceleration and deceleration time, the time unit is optional(0.01s,0.1s,1s), the max is 1000 minutes | ||
brake | Power consumption brake | The brake unit can be connected externally between P+ and P- when it is necessary | |
DC brake | Optional start-up and stop, action frequency 0~15Hz,action current 0~100%,action time 0~30.0s | ||
Jog | JOG frequency range: 0.00–upper limiting frequency JOG acceleration/deceleration time: 0.0–6000.0s | ||
Multi-section speed running | Multi-section speed operation can be achieved by interior PLC or control terminal. As many as 15sections, which has their own acceleration and deceleration time. The interior PLC supports power down save. | ||
Interior PID controller | It realizes process-controlled closed loop control systemeasily. | ||
Automatic energy-saving operation | Optimize automatically V/F curve base on condition of loading, achieving energy-saving operation. | ||
Automatic voltage regulate(AVR) | It can keep constant output voltage automatically when themains voltage changes | ||
Automatic current limiting | The current is limited automatically during the running process so as to avoid frequent tripping due to over current | ||
carrier modulation | The carrier is automatically adjusted based on the load features | ||
Speed tracking restart | Make the rotating motor smooth start without shocking | ||
Running function | Running order specified channel | Keypad specified, control terminal setting, communication setting, which can be changed by many ways | |
Running frequency specified channel | Main and complement setting realizing a main adjustment and fine tuning control. Digital setting, analog setting, impulse setting, pulse-width setting, communication ssetting and other settings can be switch freely | ||
Binding function | Running order channel and frequency specified channel can be bond arbitrarily, change synchronously | ||
Input and Output character | Digital input termina | 8 digital input (DI) terminals, the max frequency is1KHz, one of which support up to 50KHz. The digital terminal can be expanded to 14 terminals. | |
Analog input channel | 2 analog input (AI) terminal, AI1 can choose 4~20mA or 0~10V as output,AI2 is differential input, 4~20mA or -10~10V input is available. The analog terminal can be expanded to 4 terminals | ||
Pulse output channel | Impulse square wave signal output of 0~20KHZ, can realize output of physical quantity such as setting frequency, output frequency etc. | ||
Analog output terminal | 2 analog signal output terminal, AO1 can be 4~20mA or 0~10V, AO2 can be 4~20mA or 0~10V; through them the inverter can realize output of physical quantity such as setting frequency, output frequency etc. And can be expanded to 4 channel output. This output analog terminal can be expanded to 4 terminals | ||
Unique feature | Rapid current limiting | Limit inverter over current to the greatest degree, making it running reliably | |
Monopulse control | Suitable for the inverter with one key that controls the inverter on or off, which is simple and reliable to operate | ||
Fixed length control | Can realize fixed length control | ||
Timing control | Time range: 0.0–6500.0 minutes | ||
Virtual I/Os | 5 groups virtual input\output IO,can realize simply logical control | ||
keypad | LED display | The parameters like setting frequency, output frequency, output voltage, output current can be displayed | |
Lock the button | Lock all or part of the buttons. | ||
Protection function | Motor short-circuit detection at power-on, input/output phase loss protection, overcurrent protection, overvoltage protection, undervoltage protection, overheat protection and overload protection, relay protection, terminal protection and non stop protection when power off. | ||
Ambient | Use ambient | Indoor, free from direct sunlight, dust, corrosive gas, combustible gas, oil smoke, vapour, drip or salt. | |
Altitude | Less than 1000 meters.(increase every 1000m above 1000m, derate 10%) | ||
Ambient temperature | -10 degree celsius~+40 degree celsius(under ambient temperature 40degree celsius~50degree celsius,please reduce the volume or strengthen heat sink) | ||
Ambient humidity | Less than 95%RH,without condenses | ||
vibration | Smaller than 5.9m/s ²(0.6g) | ||
Storage temperature | -40degree celsius~+70degree celsius | ||
structure | Protection level | IP20 | |
Cooking mode | Temperature control | ||
Mounting mode | Wall hanging and cabinet installation |